The Master Science Class B Benchtop Autoclave is a compact vacuum steam sterilizer for wrapped instruments, porous loads and hollow items that a simple gravity autoclave cannot reliably reach. Three pre-vacuum pulses remove air from the chamber before sterilization, and a built-in steam generator supplies saturated steam quickly.
It is available with 18 L, 23 L and 45 L chambers. A microcomputer controls each phase, the LED touch panel shows the cycle status, and a built-in printer records the result, so the Master Science Class B Benchtop Autoclave suits clinics, dental practices and laboratories that need documented sterilization.
Technical Specifications
Technical data of the Master Science Class B Benchtop Autoclave:
- Brand: Master Science
- Model Number: MSSTB-B18ZSWISS, MSSTB-B23ZSWISS, MSSTB-B45ZSWISS
- SKU: MSSTB-B18ZSWISS, MSSTB-B23ZSWISS, MSSTB-B45ZSWISS
- Brand: Master Science
- Models: MSSTB-B18ZSWISS (18 L), MSSTB-B23ZSWISS (23 L), MSSTB-B45ZSWISS (45 L)
- SKU: MSSTB-B18ZSWISS, MSSTB-B23ZSWISS, MSSTB-B45ZSWISS
- Chamber Size: 18 L: Ø250 × 360 mm; 23 L: Ø250 × 450 mm; 45 L: Ø320 × 615 mm
- Power: 18 L / 23 L: 2.2 kW; 45 L: 3.5 kW
- Voltage: AC 220/110 V, 50/60 Hz
- Design Pressure: 0.25 MPa
- Design Temperature: 139°C
- Rated Working Pressure: 0.22 MPa
- Rated Working Temperature: 134°C
- Sterilization Temperature: 116 to 134°C
- Sterilization Time: 4 to 120 min
- Drying Time: 0 to 240 min
- Outer Dimensions: 18 L / 23 L: 505 × 710 × 450 mm; 45 L: 660 × 850 × 570 mm
Key Benefits
- Reliable air removal: Three pre-vacuum pulses pull air out of wrapped packs and lumens before steam enters.
- Fast steam supply: The built-in steam generator delivers saturated steam quickly for shorter cycles.
- Verified performance: BD, Helix and vacuum test programmes let you check the sterilizer routinely.
- Dry loads: An adjustable drying phase of up to 240 minutes leaves instruments ready for storage.
For high-volume media and waste sterilization, see the Class N vertical autoclave 40L to 80L.
Product Features
Chamber and Door
- Stainless steel inner chamber with sealed lid
- Automatic door switch
- Safety door lock and interlock
Control and Monitoring
- Microcomputer control
- LED display with touch operation
- Built-in printer
- Standard test interface
- Buzzer and automatic stop at the end of the cycle
Sterilization Process
- Three pre-vacuum pulses
- Automatic cold air discharge
- Automatic steam exhaust after sterilization
- Built-in steam generator
Test Programmes
- Bowie-Dick (BD) test
- Helix test
- Vacuum leak test
Protection
- Over-temperature protection
- Over-pressure protection
- Low water level protection
- Anti-dry-burning protection
Applications
The Master Science Class B Benchtop Autoclave is used in:
- Dental clinics and hospital outpatient units
- Sterilization of wrapped and hollow surgical instruments
- Laboratory sterilization of porous and textile loads
- Beauty, tattoo and podiatry clinics
- Veterinary practices
Standard Accessories Included
- Autoclave main unit with built-in printer
Optional Accessories
- Printer paper for the built-in printer
Problems the Master Science Class B Benchtop Autoclave Solves
Gravity autoclaves can leave air pockets in packs and hollow instruments. The Master Science Class B Benchtop Autoclave is designed to overcome:
- Trapped air in wrapped loads: Pre-vacuum pulses remove air so steam reaches every surface.
- Wet packs after the cycle: The programmable drying phase removes moisture before unloading.
- No proof of sterilization: The built-in printer and test cycles provide records for each run.
- Low water or overheating risks: Low water, over-temperature and over-pressure protection stop the unit safely.