The Master Science Flame AAS Analyzer is a double-beam atomic absorption spectrometer with built-in data processing and an LCD display, ready to measure metals by flame absorption, flame emission, graphite furnace and hydride generation. The double-beam path compensates for lamp, wavelength and electronic drift, giving a steady baseline from the first sample.
Hollow cathode lamps need only a short warm-up, so multi-element work starts quickly, and the titanium alloy burner reaches thermal balance fast without water cooling.
Technical Specifications
Specifications of the Master Science Flame AAS Analyzer:
- Brand: Master Science
- Model Number: MSSP-IAA320SWISS
- SKU: MSSP-IAA320SWISS
- Atomization: Flame (graphite furnace and hydride generation optional)
- Optical System: Double beam, total reflection optics
- Wavelength Range: 190 to 900 nm
- Wavelength Accuracy: ≤ ±0.5 nm
- Wavelength Repeatability: ≤ 0.3 nm (single direction)
- Spectral Bandwidth: 0.2, 0.4, 0.7, 1.4, 2.4, 5.0 nm
- Resolution: < 40 %
- Grating: 1800 lines/mm
- Baseline Stability: ±0.004 Abs/30 min
- Characteristic Concentration: ≤ 0.04 µg/mL/1% (Cu)
- Detection Limit: ≤ 0.008 µg/mL (Cu)
- Background Correction: Deuterium lamp, greater than 30×
- Data Output: RS232; PC interface
- Printer: Optional
- Power Supply: 220 V, 3 A, 50 Hz
- Gross Weight: 138 kg (main unit); 56 kg (accessories)
- Package Size: 1260 × 800 × 770 mm (main unit); 560 × 460 × 1400 mm (accessories)
Key Benefits
- Stable baseline: the double-beam optics cancel lamp and temperature drift automatically.
- Quick start: lamps need no long preheating, so analysis can begin almost immediately.
- Precise flame conditions: pressure and flow stabilisers keep the flame steady and noise low in the Master Science Flame AAS Analyzer.
- Higher light throughput: total-reflection optics and beam shaping increase the energy reaching the slit.
- Low upkeep burner: the corrosion-resistant titanium burner works without water cooling.
For higher-throughput labs, compare it with the Master Science PC-controlled AAS with eight-lamp turret.
Product Features
Data Processing
- Integral holding, peak height and peak area modes
- Auto zero and deuterium background correction
- Linear and non-linear curve fitting
- On-screen curves and report printing; PC interface
Optics and Atomization
- Total reflection optical path free of chromatic error
- Fine light beam through the flame for low characteristic concentration
- Titanium alloy 10 cm burner
Gas System
- Precision pressure and flow stabilisation
- Quick gas changeover and safety protection for air-acetylene flame
Applications
The Master Science Flame AAS Analyzer is used for:
- Heavy metal testing in water and wastewater
- Metals in food, feed and agricultural samples
- Soil and geological analysis
- Metallurgical and alloy testing
- Teaching and research laboratories
Standard Accessories Included
- Oil-free air compressor
- Glass nebulizer
- Cu hollow cathode lamp
- Nebulizer unit
- Burner unit
- Dust cover
- Water-separating gas filter
- 10 cm titanium burner
Optional Accessories
- GRD-3202 graphite furnace system
- Hydride generator
- Additional hollow cathode lamps
- Graphite tubes
- PC software
- Recirculating cooling water system
Common Laboratory Problems and How This AAS Helps
How the Master Science Flame AAS Analyzer handles everyday problems in metal analysis:
- Baseline wander: double-beam correction keeps readings stable.
- Slow element changes: short lamp warm-up speeds multi-element work.
- Noisy flame signal: stabilised gas flow lowers noise.
- Burner corrosion: titanium alloy construction resists attack.
- Need for lower detection limits: graphite furnace and hydride options extend the range.