The Master Science Karl Fischer Titrator brings volumetric and coulometric KF titration together in one instrument, so the same unit can measure percent-level water and trace moisture down to a few micrograms. A 7-inch high-contrast touchscreen guides each method from titer determination to the final result.
Oven sampling is supported for solids, gases and samples that do not dissolve readily, and a sealed solvent manager handles filling, draining and burette cleaning safely.
Technical Specifications
Specifications of the Master Science Karl Fischer Titrator:
- Brand: Master Science
- Model Number: MSTITR-50VCSWISS
- SKU: MSTITR-50VCSWISS
- Titration Types: Volumetric and coulometric Karl Fischer
- Volumetric Water Range: 100 µg to 250.0 mg
- Volumetric Resolution: 1 µg
- Coulometric Water Range: 3.0 µg to 200 mg
- Coulometric Resolution: 0.1 µg
- Water Repeatability: ≤ 0.3 %
- Units: µg, mg, %, ppm, µg/mL, mg/L
- mV Range / Resolution: 0 to 2000 mV / 0.1 mV
- Polarisation Current: 1 to 200 µA, ±3 %, fluctuation ±2.5 %/30 min
- Generator Current Accuracy: ±0.5 %, fluctuation ±0.2 %/10 min
- Methods: Auto titration, titer determination, oven, oven blank, coefficient correction
- Drift Correction: Automatic or manual
- Data Storage: 2000 titration records (GLP)
- User Management: Three levels with passwords
- Interfaces: RS232 printer, USB PC, U-disk CSV/PDF, barcode scanner, oven, balance
- Display: 7-inch color touchscreen
- Power Supply: AC 100 to 240 V, 47 to 63 Hz
- Dimensions: 240 × 370 × 270 mm
- Net Weight: About 4 kg
Key Benefits
- One instrument, two techniques: the Master Science Karl Fischer Titrator switches between volumetric and coulometric KF without a second unit.
- Trace and high moisture covered: water from 3 µg to 250 mg is measured with ≤ 0.3 % repeatability.
- Safer reagent handling: the solvent manager uses leak-proof and anti-spill bottles.
- Accurate results: automatic drift compensation corrects for moisture ingress.
- Compliance support: user levels, GMP logs and GLP storage track every result.
For acid-base and redox titrations, see the Master Science automatic potentiometric titrator.
Product Features
Volumetric KF
- Auto titration and titer determination
- Oven and oven blank methods
- Solvent manager fills, drains and cleans the burette
Coulometric KF
- Trace water down to 3 µg
- Oven, blank and coefficient correction methods
- Generator electrode included
Data
- 2000 stored results
- CSV and PDF export
- PC, printer, barcode and balance connection
Applications
The Master Science Karl Fischer Titrator is used for water determination in:
- Pharmaceutical APIs and excipients
- Petroleum products, oils and transformer oil
- Plastics, polymers and powders
- Food ingredients and edible oils
- Solvents and fine chemicals
Standard Accessories Included
- Solvent manager
- 10 mL burette
- Volumetric titration vessel with measuring electrode
- Coulometric titration vessel with measuring electrode
- Generator electrode
Optional Accessories
- KF oven
- GMP software
- Printer, barcode scanner and balance
Common Laboratory Problems and How This KF Titrator Helps
How the Master Science Karl Fischer Titrator helps with typical moisture testing problems:
- Need for two separate KF instruments: both techniques run on one unit.
- Spills of KF reagents: sealed solvent handling protects staff.
- Drift from ambient humidity: automatic drift correction keeps results accurate.
- Insoluble samples: oven sampling releases water before titration.
- Data integrity requirements: GMP logs and user control are available.